- Network Working Group T. Cox
- Request For Comments: 1304 K. Tesink
- Editors
- Bell Communications Research
- February 1992
-
-
- Definitions of Managed Objects
- for the SIP Interface Type
-
- Status of this Memo
-
- This RFC specifies an IAB standards track protocol for the Internet
- community, and requests discussion and suggestions for improvements.
- Please refer to the current edition of the "IAB Official Protocol
- Standards" for the standardization state and status of this protocol.
- Distribution of this memo is unlimited.
-
- Abstract
-
- This memo defines a portion of the Management Information Base (MIB)
- for use with network management protocols in TCP/IP-based internets.
- In particular, it defines objects for managing SIP (SMDS Interface
- Protocol) objects.
-
- Table of Contents
-
- 1. The Network Management Framework ............................ 2
- 2. Objects ..................................................... 2
- 2.1 Format of Definitions ...................................... 3
- 3. Overview .................................................... 3
- 4. Object Definitions .......................................... 4
- 4.1 The SIP Level 3 group ...................................... 4
- 4.2 The SIP Level 2 group ...................................... 8
- 4.3 The SIP PLCP group ......................................... 11
- 4.3.1 The SIP DS1 PLCP group ................................... 12
- 4.3.2 The SIP DS3 PLCP group ................................... 14
- 4.4 The SMDS Applications group ................................ 16
- 4.5 The SMDS Carrier Selection group ........................... 18
- 4.6 The SIP Error Log group .................................... 18
- 5. Acknowledgments ............................................. 23
- 6. References .................................................. 23
- 7. Security Considerations...................................... 25
- 8. Authors' Addresses........................................... 25
-
-
-
-
-
-
-
- SNMP Working Group [Page 1]
-
- RFC 1304 SIP Objects February 1992
-
-
- 1. The Network Management Framework
-
- The Internet-standard Network Management Framework consists of three
- components. They are:
-
- RFC 1155 [3] which defines the SMI, the mechanisms used for
- describing and naming objects for the purpose of management. RFC
- 1212 [9] defines a more concise description mechanism, which is
- wholly consistent with the SMI.
-
- RFC 1156 [4] which defines MIB-I, the core set of managed objects
- for the Internet suite of protocols. RFC 1213 [6], defines MIB-
- II, an evolution of MIB-I based on implementation experience and
- new operational requirements.
-
- RFC 1157 [5] which defines the SNMP, the protocol used for network
- access to managed objects.
-
- The Framework permits new objects to be defined for the purpose of
- experimentation and evaluation.
-
- 2. Objects
-
- Managed objects are accessed via a virtual information store, termed
- the Management Information Base or MIB. Objects in the MIB are
- defined using the subset of Abstract Syntax Notation One (ASN.1)
- International Standard 8824 [7] defined in the SMI. In particular,
- each object has a name, a syntax, and an encoding. The name is an
- object identifier, an administratively assigned name, which specifies
- an object type. The object type together with an object instance
- serves to uniquely identify a specific instantiation of the object.
- For human convenience, we often use a textual string, termed the
- OBJECT DESCRIPTOR, to also refer to the object type.
-
- The syntax of an object type defines the abstract data structure
- corresponding to that object type. The ASN.1 language is used for
- this purpose. However, the SMI RFC 1155 [3] purposely restricts the
- ASN.1 constructs which may be used. These restrictions are
- explicitly made for simplicity.
-
- The encoding of an object type is simply how that object type is
- represented using the object type's syntax. Implicitly tied to the
- notion of an object type's syntax and encoding is how the object type
- is represented when being transmitted on the network. The SMI
- specifies the use of the basic encoding rules of ASN.1 International
- Standard 8825 [8], subject to the additional requirements imposed by
- the SNMP.
-
-
-
-
- SNMP Working Group [Page 2]
-
- RFC 1304 SIP Objects February 1992
-
-
- 2.1. Format of Definitions
-
- Section 4 contains contains the specification of all object types
- contained in this MIB module. The object types are defined using the
- conventions defined in the SMI, as amended by the extensions
- specified in RFC 1212 [9].
-
- 3. Overview
-
- These objects are used when the particular media being used to
- realize an interface is a SIP interface. At present, this applies to
- these values of the ifType variable in the Internet-standard MIB:
-
- sip (31)
-
- For these interfaces, the value of the ifSpecific variable in the
- MIB-II [6] has the OBJECT IDENTIFIER value:
-
- sip OBJECT IDENTIFIER ::= { transmission 31 }
-
- The definitions contained herein are based on the SIP specifications
- in Bellcore TR-TSV-000772 and TR-TSV-000773 [11,12].
-
- The SIP (SMDS Interface Protocol) protocol stack is defined as
- follows in TR-TSV-000772 [11]:
-
- ___________________
- | |
- | SIP Level 3 [11] |
- |___________________|
- | |
- | SIP Level 2 [11] |
- |___________________|
- | |
- | PLCP [12] |
- |___________________|
- | |
- | DS1 or DS3 [12] |
- |___________________|
-
- The PLCP (Physical Layer Convergence Procedure) adapts the
- capabilities of the transmission system (DS1 or DS3 formats) to the
- service expected by SIP Level 2. Managed objects for DS1 and DS3
- Interface Types are defined in RFC 1232 [13] and RFC 1233 [14]
- respectively (and amended in RFC 1239 [17]), and can be utilized for
- management of SIP interfaces. This document defines managed objects
- for the remaining protocol levels of the SIP Interface Type. This
- document does not specify objects for the management of subscription
-
-
-
- SNMP Working Group [Page 3]
-
- RFC 1304 SIP Objects February 1992
-
-
- or configuration of Subscriber-Network Interfaces (SNIs). Those
- objects are defined in Definitions of Managed Objects for SMDS
- Subscription [18]. Bellcore requirements on these objects are
- specified in TA-TSV-001062 [16].
-
- 4. Object Definitions
-
- RFC1304-MIB DEFINITIONS ::= BEGIN
-
- IMPORTS
- Counter, TimeTicks, IpAddress
- FROM RFC1155-SMI
- transmission
- FROM RFC1213-MIB
- OBJECT-TYPE
- FROM RFC-1212;
-
- -- This MIB module uses the extended OBJECT-TYPE macro
- -- as defined in RFC-1212.
-
- -- This is the MIB module for the SIP objects.
-
-
- sip OBJECT IDENTIFIER ::= { transmission 31 }
-
- -- All representations of SMDS addresses in this MIB
- -- module use, as a textual convention (i.e., this
- -- convention does not affect their encoding), the
- -- data type:
-
- SMDSAddress ::= OCTET STRING (SIZE (8))
- -- the 60-bit SMDS address, preceded by 4 bits with the
- -- following values:
- -- "1100" when representing an individual address
- -- "1110" when representing a group address
-
-
- -- The SIP Level 3 group
- -- Implementation of the SIP Level 3 group is mandatory
- -- for all systems implementing SIP Level 3.
-
- sipL3Table OBJECT-TYPE
- SYNTAX SEQUENCE OF SipL3Entry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "This table contains SIP L3 parameters and
- state variables, one entry per SIP port."
-
-
-
- SNMP Working Group [Page 4]
-
- RFC 1304 SIP Objects February 1992
-
-
- ::= { sip 1 }
-
- sipL3Entry OBJECT-TYPE
- SYNTAX SipL3Entry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "This list contains SIP L3 parameters and
- state variables."
- INDEX { sipL3Index }
- ::= { sipL3Table 1 }
-
- SipL3Entry ::= SEQUENCE {
- sipL3Index
- INTEGER,
- sipL3ReceivedIndividualDAs
- Counter,
- sipL3ReceivedGAs
- Counter,
- sipL3UnrecognizedIndividualDAs
- Counter,
- sipL3UnrecognizedGAs
- Counter,
- sipL3SentIndividualDAs
- Counter,
- sipL3SentGAs
- Counter,
- sipL3Errors
- Counter,
- sipL3InvalidSMDSAddressTypes
- Counter,
- sipL3VersionSupport
- INTEGER
- }
-
- sipL3Index OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The value of this object identifies the SIP
- port interface for which this entry contains
- management information. The value of this
- object for a particular interface has the same
- value as the ifIndex object, defined in RFC
- 1156 and RFC 1213, for the same interface."
- ::= { sipL3Entry 1 }
-
-
-
-
- SNMP Working Group [Page 5]
-
- RFC 1304 SIP Objects February 1992
-
-
- sipL3ReceivedIndividualDAs OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The total number of individually addressed SIP
- Level 3 PDUs received from the remote system
- across the SNI. The total includes only
- unerrored L3PDUs."
- ::= { sipL3Entry 2 }
-
- sipL3ReceivedGAs OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The total number of group addressed SIP Level 3
- PDUs received from the remote system across the
- SNI. The total includes only unerrored L3PDUs."
- ::= { sipL3Entry 3 }
-
- sipL3UnrecognizedIndividualDAs OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of SIP Level 3 PDUs received from the
- remote system with invalid or unknown individual
- destination addresses (Destination Address
- Screening violations are not included). See SMDS
- Subscription MIB module."
- ::= { sipL3Entry 4 }
-
- sipL3UnrecognizedGAs OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of SIP Level 3 PDUs received from the
- remote system with invalid or unknown group
- addresses. (Destination Address Screening
- violations are not included). See SMDS
- Subscription MIB module."
- ::= { sipL3Entry 5 }
-
- sipL3SentIndividualDAs OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
-
-
-
- SNMP Working Group [Page 6]
-
- RFC 1304 SIP Objects February 1992
-
-
- STATUS mandatory
- DESCRIPTION
- "The number of individually addressed SIP Level 3
- PDUs that have been sent by this system across the
- SNI."
- ::= { sipL3Entry 6 }
-
- sipL3SentGAs OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of group addressed SIP L3PDUs that
- have been sent by this system across the SNI."
- ::= { sipL3Entry 7 }
-
- -- The total number of SIP L3PDU errors can be calculated as
- -- (Syntactic errors + Semantic Service errors )
- -- Syntactic errors include:
- -- sipL3Errors
- -- Latest occurrences of syntactic error types are logged in
- -- sipL3PDUErrorTable.
- -- Semantic Service errors include:
- -- sipL3UnrecognizedIndividualDAs
- -- sipL3UnrecognizedGAs
- -- sipL3InvalidSMDSAddressTypes
- -- Note that public networks supporting SMDS may discard
- -- SIP L3PDUs due to subscription violations. Related
- -- managed objects are defined in Definitions of Managed
- -- Objects for SMDS Subscription.
-
-
- sipL3Errors OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The total number of SIP Level 3 PDUs received
- from the remote system that were discovered to
- have errors (including protocol processing and bit
- errors but excluding addressing-related errors)
- and were discarded. Includes both group addressed
- L3PDUs and L3PDUs containing an individual
- destination address."
- ::= { sipL3Entry 8 }
-
-
-
-
-
-
- SNMP Working Group [Page 7]
-
- RFC 1304 SIP Objects February 1992
-
-
- sipL3InvalidSMDSAddressTypes OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of SIP Level 3 PDUs received from the
- remote system that had the Source or Destination
- Address_Type subfields, (the four most significant
- bits of the 64 bit address field), not equal to
- the value 1100 or 1110. Also, an error is
- considered to have occurred if the Address_Type
- field for a Source Address, the four most
- significant bits of the 64 bits, is equal to 1110
- (a group address)."
- ::= { sipL3Entry 9 }
-
- sipL3VersionSupport OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "A value which indicates the version(s) of SIP
- that this interface supports. The value is a sum.
- This sum initially takes the value zero. For each
- version, V, that this interface supports, 2 raised
- to (V - 1) is added to the sum. For example, a
- port supporting versions 1 and 2 would have a
- value of (2^(1-1)+2^(2-1))=3. The
- sipL3VersionSupport is effectively a bit mask with
- Version 1 equal to the least significant bit
- (LSB)."
- ::= { sipL3Entry 10 }
-
-
- -- The SIP Level 2 group
- -- Implementation of the SIP Level 2 group is mandatory
- -- for all systems implementing SIP Level 2.
-
-
- sipL2Table OBJECT-TYPE
- SYNTAX SEQUENCE OF SipL2Entry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "This table contains SIP L2PDU parameters and
- state variables, one entry per SIP port."
- ::= { sip 2 }
-
-
-
-
- SNMP Working Group [Page 8]
-
- RFC 1304 SIP Objects February 1992
-
-
- sipL2Entry OBJECT-TYPE
- SYNTAX SipL2Entry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "This list contains SIP L2 parameters and state
- variables."
- INDEX { sipL2Index }
- ::= { sipL2Table 1 }
-
- SipL2Entry ::= SEQUENCE {
- sipL2Index
- INTEGER,
- sipL2ReceivedCounts
- Counter,
- sipL2SentCounts
- Counter,
- sipL2HcsOrCRCErrors
- Counter,
- sipL2PayloadLengthErrors
- Counter,
- sipL2SequenceNumberErrors
- Counter,
- sipL2MidCurrentlyActiveErrors
- Counter,
- sipL2BomOrSSMsMIDErrors
- Counter,
- sipL2EomsMIDErrors
- Counter
- }
-
- sipL2Index OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The value of this object identifies the SIP port
- interface for which this entry contains management
- information. The value of this object for a
- particular interface has the same value as the
- ifIndex object, defined in RFC 1156 and RFC 1213,
- for the same interface."
- ::= { sipL2Entry 1 }
-
- sipL2ReceivedCounts OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
-
-
-
- SNMP Working Group [Page 9]
-
- RFC 1304 SIP Objects February 1992
-
-
- DESCRIPTION
- "The number of SIP Level 2 PDUs received from the
- remote system across the SNI. The total includes
- only unerrored L2PDUs."
- ::= { sipL2Entry 2 }
-
- sipL2SentCounts OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of SIP Level 2 PDUs that have been
- sent by this system across the SNI."
- ::= { sipL2Entry 3 }
-
- -- The total number of SIP L2PDU errors can be calculated as
- -- the sum of:
- -- sipL2HcsOrCRCErrors
- -- sipL2PayloadLengthErrors
- -- sipL2SequenceNumberErrors
- -- sipL2MidCurrentlyActiveErrors
- -- sipL2BomOrSSMsMIDErrors
- -- sipL2EomsMIDErrors
-
- sipL2HcsOrCRCErrors OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of received SIP Level 2 PDUs that were
- discovered to have either a Header Check Sequence
- error or a Payload CRC violation."
- ::= { sipL2Entry 4 }
-
- sipL2PayloadLengthErrors OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of received SIP Level 2 PDUs that had
- Payload Length errors that fall in the following
- specifications:
- - SSM L2_PDU payload length field value less
- - than 28 octets or greater than 44 octets,
-
- - BOM or COM L2_PDU payload length field not
- - equal to 44 octets,
-
-
-
-
- SNMP Working Group [Page 10]
-
- RFC 1304 SIP Objects February 1992
-
-
- - EOM L2_PDU payload length field value less
- - than 4 octets or greater than 44 octets."
- ::= { sipL2Entry 5 }
-
- sipL2SequenceNumberErrors OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of received SIP Level 2 PDUs that had
- a sequence number within the L2PDU not equal to
- the expected sequence number of the SMDS SS
- receive process."
- ::= { sipL2Entry 6 }
-
- sipL2MidCurrentlyActiveErrors OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of received SIP Level 2 PDUs that are
- BOMs for which an active receive process is
- already started."
- ::= { sipL2Entry 7 }
-
- sipL2BomOrSSMsMIDErrors OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of received SIP Level 2 PDUs that are
- SSMs with a MID not equal to zero or are BOMs with
- MIDs equal to zero."
- ::= { sipL2Entry 8 }
-
- sipL2EomsMIDErrors OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The number of received SIP Level 2 PDUs that are
- EOMs for which there is no active receive process
- for the MID (i.e., the receipt of an EOM which
- does not correspond to a BOM) OR the EOM has a MID
- equal to zero."
- ::= { sipL2Entry 9 }
-
-
-
-
-
- SNMP Working Group [Page 11]
-
- RFC 1304 SIP Objects February 1992
-
-
- -- The SIP PLCP group
- -- Implementation of one of these groups is mandatory
- -- if the PLCP is implemented.
-
- sipPLCP OBJECT IDENTIFIER ::= { sip 3 }
-
-
- -- The SIP DS1 PLCP group
- -- Implementation of this group is mandatory
- -- if the DS1 PLCP is implemented.
-
- sipDS1PLCPTable OBJECT-TYPE
- SYNTAX SEQUENCE OF SipDS1PLCPEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "This table contains SIP DS1 PLCP parameters and
- state variables, one entry per SIP port."
- ::= { sipPLCP 1 }
-
- sipDS1PLCPEntry OBJECT-TYPE
- SYNTAX SipDS1PLCPEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "This list contains SIP DS1 PLCP parameters and
- state variables."
- INDEX { sipDS1PLCPIndex }
- ::= { sipDS1PLCPTable 1 }
-
- SipDS1PLCPEntry ::= SEQUENCE {
- sipDS1PLCPIndex
- INTEGER,
- sipDS1PLCPSEFSs
- Counter,
- sipDS1PLCPAlarmState
- INTEGER,
- sipDS1PLCPUASs
- Counter
- }
-
-
- sipDS1PLCPIndex OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The value of this object identifies the SIP port
-
-
-
- SNMP Working Group [Page 12]
-
- RFC 1304 SIP Objects February 1992
-
-
- interface for which this entry contains management
- information. The value of this object for a
- particular interface has the same value as the
- ifIndex object, defined in RFC 1156 and RFC 1213,
- for the same interface."
- ::= { sipDS1PLCPEntry 1 }
-
-
- sipDS1PLCPSEFSs OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "A DS1 Severely Errored Framing Second (SEFS) is a
- count of one-second intervals containing one or
- more SEF events. A Severely Errored Framing (SEF)
- event is declared when an error in the A1 octet
- and an error in the A2 octet of a framing octet
- pair (i.e., errors in both framing octets), or two
- consecutive invalid and/or nonsequential Path
- Overhead Identifier octets are detected."
- ::= { sipDS1PLCPEntry 2 }
-
- sipDS1PLCPAlarmState OBJECT-TYPE
- SYNTAX INTEGER {
- noAlarm (1),
- receivedFarEndAlarm (2),
- incomingLOF (3)
- }
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "This variable indicates if there is an alarm
- present for the DS1 PLCP. The value
- receivedFarEndAlarm means that the DS1 PLCP has
- received an incoming Yellow Signal, the value
- incomingLOF means that the DS1 PLCP has declared a
- loss of frame (LOF) failure condition, and the
- value noAlarm means that there are no alarms
- present. See TR-TSV-000773 for a description of
- alarm states."
- ::= { sipDS1PLCPEntry 3 }
-
-
- sipDS1PLCPUASs OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
-
-
-
- SNMP Working Group [Page 13]
-
- RFC 1304 SIP Objects February 1992
-
-
- DESCRIPTION
- "The counter associated with the number of
- Unavailable Seconds, as defined by TR-TSV-000773,
- encountered by the PLCP."
- ::= { sipDS1PLCPEntry 4 }
-
-
- -- The SIP DS3 PLCP group
- -- Implementation of this group is mandatory
- -- if the DS3 PLCP is implemented.
-
- sipDS3PLCPTable OBJECT-TYPE
- SYNTAX SEQUENCE OF SipDS3PLCPEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "This table contains SIP DS3 PLCP parameters and
- state variables, one entry per SIP port."
- ::= { sipPLCP 2 }
-
- sipDS3PLCPEntry OBJECT-TYPE
- SYNTAX SipDS3PLCPEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "This list contains SIP DS3 PLCP parameters and
- state variables."
- INDEX { sipDS3PLCPIndex }
- ::= { sipDS3PLCPTable 1 }
-
- SipDS3PLCPEntry ::= SEQUENCE {
- sipDS3PLCPIndex
- INTEGER,
- sipDS3PLCPSEFSs
- Counter,
- sipDS3PLCPAlarmState
- INTEGER,
- sipDS3PLCPUASs
- Counter
- }
-
-
- sipDS3PLCPIndex OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The value of this object identifies the SIP port
-
-
-
- SNMP Working Group [Page 14]
-
- RFC 1304 SIP Objects February 1992
-
-
- interface for which this entry contains management
- information. The value of this object for a
- particular interface has the same value as the
- ifIndex object, defined in RFC 1156 and RFC 1213,
- for the same interface."
- ::= { sipDS3PLCPEntry 1 }
-
- sipDS3PLCPSEFSs OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "A DS3 Severely Errored Framing Second (SEFS) is a
- count of one-second intervals containing one or
- more SEF events. A Severely Errored Framing (SEF)
- event is declared when an error in the A1 octet
- and an error in the A2 octet of a framing octet
- pair (i.e., errors in both framing octets), or two
- consecutive invalid and/or nonsequential Path
- Overhead Identifier octets are detected."
- ::= { sipDS3PLCPEntry 2 }
-
- sipDS3PLCPAlarmState OBJECT-TYPE
- SYNTAX INTEGER {
- noAlarm (1),
- receivedFarEndAlarm (2),
- incomingLOF (3)
- }
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "This variable indicates if there is an alarm
- present for the DS3 PLCP. The value
- receivedFarEndAlarm means that the DS3 PLCP has
- received an incoming Yellow Signal, the value
- incomingLOF means that the DS3 PLCP has declared a
- loss of frame (LOF) failure condition, and the
- value noAlarm means that there are no alarms
- present. See TR-TSV-000773 for a description of
- alarm states."
- ::= { sipDS3PLCPEntry 3 }
-
-
- sipDS3PLCPUASs OBJECT-TYPE
- SYNTAX Counter
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
-
-
-
- SNMP Working Group [Page 15]
-
- RFC 1304 SIP Objects February 1992
-
-
- "The counter associated with the number of
- Unavailable Seconds, as defined by TR-TSV-000773,
- encountered by the PLCP."
- ::= { sipDS3PLCPEntry 4 }
-
-
- -- The SMDS Applications group
- -- Applications that have been identified for this group are:
- -- * IP-over-SMDS (details are specified in RFC 1209)
- -- Implementation of this group is mandatory for systems
- -- that implement IP-over-SMDS Interface Protocol.
-
- smdsApplications OBJECT IDENTIFIER ::= { sip 4 }
-
- ipOverSMDS OBJECT IDENTIFIER ::= { smdsApplications 1 }
-
- -- Although the objects in this group are read-only, at the
- -- agent's discretion they may be made read-write so that the
- -- management station, when appropriately authorized, may
- -- change the addressing information related to the
- -- configuration of a logical IP subnetwork implemented on
- -- top of SMDS.
-
- -- This table is necessary to support RFC1209 (IP-over-SMDS)
- -- and gives information on the Group Addresses and ARP
- -- Addresses used in the Logical IP subnetwork.
- -- One SMDS address may be associated with multiple IP
- -- addresses. One SNI may be associated with multiple LISs.
-
- ipOverSMDSTable OBJECT-TYPE
- SYNTAX SEQUENCE OF IpOverSMDSEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "The table of addressing information relevant to
- this entity's IP addresses."
- ::= { ipOverSMDS 1 }
-
- ipOverSMDSEntry OBJECT-TYPE
- SYNTAX IpOverSMDSEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "The addressing information for one of this
- entity's IP addresses."
- INDEX { ipOverSMDSIndex, ipOverSMDSAddress }
- ::= { ipOverSMDSTable 1 }
-
-
-
-
- SNMP Working Group [Page 16]
-
- RFC 1304 SIP Objects February 1992
-
-
- IpOverSMDSEntry ::=
- SEQUENCE {
- ipOverSMDSIndex
- INTEGER,
- ipOverSMDSAddress
- IpAddress,
- ipOverSMDSHA
- SMDSAddress,
- ipOverSMDSLISGA
- SMDSAddress,
- ipOverSMDSARPReq
- SMDSAddress
- }
-
- ipOverSMDSIndex OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The value of this object identifies the SIP port
- interface for which this entry contains management
- information. The value of this object for a
- particular interface has the same value as the
- ifIndex object, defined in RFC 1156 and RFC 1213,
- for the same interface."
- ::= { ipOverSMDSEntry 1 }
-
- ipOverSMDSAddress OBJECT-TYPE
- SYNTAX IpAddress
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The IP address to which this entry's addressing
- information pertains."
- ::= { ipOverSMDSEntry 2 }
-
- ipOverSMDSHA OBJECT-TYPE
- SYNTAX SMDSAddress
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The SMDS Individual address of the IP station."
- ::= { ipOverSMDSEntry 3 }
-
- ipOverSMDSLISGA OBJECT-TYPE
- SYNTAX SMDSAddress
- ACCESS read-only
- STATUS mandatory
-
-
-
- SNMP Working Group [Page 17]
-
- RFC 1304 SIP Objects February 1992
-
-
- DESCRIPTION
- "The SMDS Group Address that has been configured
- to identify the SMDS Subscriber-Network Interfaces
- (SNIs) of all members of the Logical IP Subnetwork
- (LIS) connected to the network supporting SMDS."
- ::= { ipOverSMDSEntry 4 }
-
- ipOverSMDSARPReq OBJECT-TYPE
- SYNTAX SMDSAddress
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The SMDS address (individual or group) to which
- ARP Requests are to be sent."
- ::= { ipOverSMDSEntry 5 }
-
-
- -- The SMDS Carrier Selection group
- -- This group is used as a place holder
- -- for carrier selection objects.
-
- smdsCarrierSelection OBJECT IDENTIFIER ::= { sip 5}
-
-
- -- The SIP Error Log
- -- Implementation of this group is mandatory
- -- for all systems that implement SIP Level 3.
-
- sipErrorLog OBJECT IDENTIFIER ::= { sip 6 }
-
- sipL3PDUErrorTable OBJECT-TYPE
- SYNTAX SEQUENCE OF SipL3PDUErrorEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "A table that contains the latest occurrence of
- the following syntactical SIP L3PDU errors:
-
- - Destination Address Field Format Error,
-
- The following pertains to the 60 least significant
- bits of the 64 bit address field. The 60 bits
- contained in the address subfield can be used to
- represent addresses up to 15 decimal digits. Each
- decimal digit shall be encoded into four bits
- using Binary Coded Decimal (BCD), with the most
- significant digit occurring left-most. If not all
- 15 digits are required, then the remainder of this
-
-
-
- SNMP Working Group [Page 18]
-
- RFC 1304 SIP Objects February 1992
-
-
- field shall be padded on the right with bits set
- to one. An error is considered to have occurred:
- a). if the first four bits of the address
- subfield are not BCD, OR b). if the first four
- bits of the address subfield are populated with
- the country code value 0001, AND the 40 bits which
- follow are not Binary Coded Decimal (BCD) encoded
- values of the 10 digit addresses, OR the remaining
- 16 least significant bits are not populated with
- 1's, OR c). if the address subfield is not
- correct according to another numbering plan which
- is dependent upon the carrier assigning the
- numbers and offering SMDS.
-
- - Source Address Field Format Error,
-
- The description of this parameter is the same as
- the description of the Destination Address Field
- Format Error.
-
- - Invalid BAsize Field Value,
-
- An error is considered to have occurred when the
- BAsize field of an SIP L3PDU contains a value less
- that 32, greater than 9220 octets without the
- CRC32 field present, greater than 9224 octets with
- the CRC32 field present, or not equal to a
- multiple of 4 octets,
-
- - Invalid Header Extension Length Field Value,
-
- An error is considered to have occurred when the
- Header Extension Length field value is not equal
- 3.
-
- - Invalid Header Extension - Element Length,
-
- An error is considered to have occurred when the
- Header Extension - Element Length is greater than
- 12.
-
- - Invalid Header Extension - Version Element
- Position, Length, or Value,
-
- An error is considered to have occurred when a
- Version element with Length=3, Type=0, and Value=1
- does not appear first within the Header Extension,
- or an element Type=0 appears somewhere other than
-
-
-
- SNMP Working Group [Page 19]
-
- RFC 1304 SIP Objects February 1992
-
-
- within the first three octets in the Header
- Extension.
-
- - Invalid Header Extension - Carrier Selection
- Element Position, Length, Value or Format,
-
- An error is considered to have occurred when a
- Carrier Selection element does not appear second
- within the Header Extension, if the Element Type
- does not equal 1, the Element Length does not
- equal 4, 6, or 8, the Element Value field is not
- four BCD encoded decimal digits used in specifying
- the Carrier Identification Code (CIC), or the
- identified CIC code is invalid.
-
- - Header Extension PAD Error
-
- An error is considered to have occurred when the
- Header Extension PAD is 9 octets in length, or if
- the Header Extension PAD is greater than zero
- octets in length and the Header Extension PAD does
- not follow all Header Extension elements or does
- not begin with at least one octet of all zeros.
-
- - BEtag Mismatch Error,
-
- An error is considered to have occurred when the
- Beginning-End Tags in the SIP L3PDU header and
- trailer are not equal.
-
- - BAsize Field not equal to Length Field Error,
-
- An error is considered to have occurred when the
- value of the BAsize Field does not equal the value
- of the Length Field.
-
- - Incorrect Length Error, and
-
- An error is considered to have occurred when the
- the Length field value is not equal to the portion
- of the SIP L3PDU which extends from the
- Destination Address field up to and including the
- CRC32 field (if present) or up to and including
- the PAD field (if the CRC32 field is not present).
- As an optional check, an error is considered to
- have occurred when the length of a partially
- received SIP L3PDU exceeds the BAsize value.
-
-
-
-
- SNMP Working Group [Page 20]
-
- RFC 1304 SIP Objects February 1992
-
-
- - MRI Timeout Error.
-
- An error is considered to have occurred when the
- elapsed time between receipt of BOM and
- corresponding EOM exceeds the value of the MRI
- (Message Receive Interval) for a particular
- transport signal format.
-
- An entry is indexed by interface number and error
- type, and contains Source Address, Destination
- Address and a timestamp. All these errors are
- counted in the sipL3Errors counter. When
- sipL3PDUErrorTimeStamp is equal to zero, the
- SipL3PDUErrorEntry does not contain any valid
- information."
- ::= { sipErrorLog 1 }
-
- sipL3PDUErrorEntry OBJECT-TYPE
- SYNTAX SipL3PDUErrorEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "An entry in the service disagreement table."
- INDEX { sipL3PDUErrorIndex, sipL3PDUErrorType }
- ::= { sipL3PDUErrorTable 1 }
-
- SipL3PDUErrorEntry ::= SEQUENCE {
- sipL3PDUErrorIndex
- INTEGER,
- sipL3PDUErrorType
- INTEGER,
- sipL3PDUErrorSA
- SMDSAddress,
- sipL3PDUErrorDA
- SMDSAddress,
- sipL3PDUErrorTimeStamp
- TimeTicks
- }
-
- sipL3PDUErrorIndex OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The value of this object identifies the SIP port
- interface for which this entry contains management
- information. The value of this object for a
- particular interface has the same value as the
-
-
-
- SNMP Working Group [Page 21]
-
- RFC 1304 SIP Objects February 1992
-
-
- ifIndex object, defined in RFC 1156 and RFC 1213,
- for the same interface."
- ::= { sipL3PDUErrorEntry 1 }
-
- sipL3PDUErrorType OBJECT-TYPE
- SYNTAX INTEGER {
- erroredDAFieldFormat (1),
- erroredSAFieldFormat (2),
- invalidBAsizeFieldValue (3),
- invalidHdrExtLength (4),
- invalidHdrExtElementLength (5),
- invalidHdrExtVersionElementPositionLenthOrValue (6),
- invalidHdrExtCarSelectElementPositionLenghtValueOrFormat (7),
- hePADError (8),
- beTagMismatch (9),
- baSizeFieldNotEqualToLengthField (10),
- incorrectLength (11),
- mriTimeout (12)
- }
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The type of error."
- ::= { sipL3PDUErrorEntry 2 }
-
- sipL3PDUErrorSA OBJECT-TYPE
- SYNTAX SMDSAddress
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "A rejected SMDS source address."
- ::= { sipL3PDUErrorEntry 3 }
-
- sipL3PDUErrorDA OBJECT-TYPE
- SYNTAX SMDSAddress
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "A rejected SMDS destination address."
- ::= { sipL3PDUErrorEntry 4 }
-
- sipL3PDUErrorTimeStamp OBJECT-TYPE
- SYNTAX TimeTicks
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "The timestamp for the service disagreement. The
- timestamp contains the value of sysUpTime at the
-
-
-
- SNMP Working Group [Page 22]
-
- RFC 1304 SIP Objects February 1992
-
-
- latest occurrence of this type of service
- disagreement. See textual description under
- sipL3PDUErrorTable for boundary conditions."
- ::= { sipL3PDUErrorEntry 5 }
-
- END
-
- 5. Acknowledgments
-
- This document was produced by the SNMP Working Group. In addition,
- the comments of the following individuals are also acknowledged: Ted
- Brunner, Jeff Case, Tracy Cox, Sherri Hiller, Steve Jaffe, Deirdre
- Kostick, Dave Piscitello, and Ron Reuss.
-
- 6. References
-
- [1] Cerf, V., "IAB Recommendations for the Development of Internet
- Network Management Standards", RFC 1052, NRI, April 1988.
-
- [2] Cerf, V., "Report of the Second Ad Hoc Network Management Review
- Group", RFC 1109, NRI, August 1989.
-
- [3] Rose M., and K. McCloghrie, "Structure and Identification of
- Management Information for TCP/IP-based internets", RFC 1155,
- Performance Systems International, Hughes LAN Systems, May 1990.
-
- [4] McCloghrie K., and M. Rose, "Management Information Base for
- Network Management of TCP/IP-based internets", RFC 1156, Hughes
- LAN Systems, Performance Systems International, May 1990.
-
- [5] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple
- Network Management Protocol", RFC 1157, SNMP Research,
- Performance Systems International, Performance Systems
- International, MIT Laboratory for Computer Science, May 1990.
-
- [6] McCloghrie K., and M. Rose, Editors, "Management Information
- Base for Network Management of TCP/IP-based internets", RFC
- 1213, Performance Systems International, March 1991.
-
- [7] Information processing systems - Open Systems Interconnection -
- Specification of Abstract Syntax Notation One (ASN.1),
- International Organization for Standardization, International
- Standard 8824, December 1987.
-
- [8] Information processing systems - Open Systems Interconnection -
- Specification of Basic Encoding Rules for Abstract Notation One
- (ASN.1), International Organization for Standardization,
- International Standard 8825, December 1987.
-
-
-
- SNMP Working Group [Page 23]
-
- RFC 1304 SIP Objects February 1992
-
-
- [9] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions",
- RFC 1212, Performance Systems International, Hughes LAN Systems,
- March 1991.
-
- [10] Rose, M., Editor, "A Convention for Defining Traps for use with
- the SNMP", RFC 1215, Performance Systems International, March
- 1991.
-
- [11] "Generic System Requirements in Support of Switched Multi-
- megabit Data Service", Bellcore Technical Reference, TR-TSV-
- 000772, Issue 1, May 1991.
-
- [12] "Local Access System Generic Requirements, Objectives, and
- Interfaces in Support of Switched Multi-megabit Data Service",
- Bellcore Technical Reference, TR-TSV-000773, Issue 1, June 1990.
-
- [13] Baker F., and C. Kolb, Editors, "Definitions of Managed Objects
- for the DS1 Interface Type", RFC 1232, ACC, Performance Systems
- International, Inc., May 1991.
-
- [14] Cox, T., and K. Tesink, Editors, "Definitions of Managed Objects
- for the DS3 Interface Type", RFC 1233, Bell Communications
- Research, May 1991.
-
- [15] Piscitello, D., and J. Lawrence, Editors, The Transmission of IP
- Datagrams over the SMDS Service", RFC 1209, Bell Communications
- Research, March 1991.
-
- [16] "Generic Requirements For SMDS Customer Network Management
- Service", TA-TSV-001062, Issue 1, February 1991, and Supplement
- 1, April 1991.
-
- [17] Reynolds, J., "Reassignment of Experimental MIBs to Standard
- MIBs", RFC 1239, USC/Information Sciences Institute, June 1991.
-
- [18] Tesink, K., "Definitions of Managed Objects for SMDS
- Subscription", Version 1.0, Bellcore, March 1991.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- SNMP Working Group [Page 24]
-
- RFC 1304 SIP Objects February 1992
-
-
- 7. Security Considerations
-
- Security issues are not discussed in this memo.
-
- 8. Authors' Addresses
-
- Tracy A. Cox
- Bell Communications Research
- 331 Newman Springs Road
- Red Bank, NJ 07701
-
- Phone: (908) 758-2107
- EMail: tacox@sabre.bellcore.com
-
-
- Kaj Tesink
- Bell Communications Research
- 331 Newman Springs Road
- Red Bank, NJ 07701
-
- Phone: (908) 758-5254
- EMail: kaj@nvuxr.cc.bellcore.com
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- SNMP Working Group [Page 25]
-